Level measurement in a vacuum evaporator with scraper system
Process data
Measuring task
Level measurement
Measuring point
Tank
Measuring range up to
1.6 m
Medium
Extracted solution
Process temperature
+50 ... +80 °C
Process pressure
-0.7 ... -0.5 bar
Special challenges
Vacuum, buildup, condensation, vessel internals
Application
A thickening vessel fitted with a scraper is used to increase the concentration of extracted solutions by means of evaporation under vacuum. Extremely precise level measurement is required in this process because the concentration is determined by the filling height. The evaporation system operates according to meeting specified levels. As soon as they reach the correct value, the evaporation process is stopped and the concentrated solution is discharged out of the tank.
Your benefit
Reliable
Optimal concentration thanks to highly accurate level measurement
Cost effective
Easy cleaning without dismantling
User friendly
Simple installation and setup
Recommended products
VEGAPULS 64
Vacuum evaporator level measurement with non-contact radar
Measurement down to the bottom of the vessel thanks to tight signal focusing
Reliable measurement, unaffected by vessel internals due to high dynamic range
Encapsulated antenna system, insensitive to condensation and buildup
The front-flush, encapsulated antenna is easy to clean and resistant to the extreme conditions of the CIP and SIP processes
Measuring range - Distance
30 m
Process temperature
-196 ... 200 °C
Process pressure
-1 ... 25 bar
Sorry, Currently No Video Uploaded.
Sorry, Currently No File Uploaded.
Level measurement in a vacuum evaporator with scraper system
Please Leave Your Product Enquiry Here. We will Get Back To You Soon.