Level measurement and point level detection in hexane storage tank
Process data
Measuring task
Level measurement and point level detection
Measuring point
Tank
Measuring range up to
15 m
Medium
n-Hexane
Process temperature
-40 … +50 °C
Process pressure
0 … +6 bar
Special challenges
Media with low dielectric constant
Application
In pharmaceutical production, Hexane is a commonly used solvent and reaction medium, as well as an agent for oil and grease extraction. This colourless liquid has a slight petrol odour and is highly volatile light hydrocarbon, readily forming highly flammable vapour-air mixtures. When the tank is emptied, no residues may remain inside. Reliable level measurement and overfill protection is an absolute necessity for safe storage and handling.
Your benefit
Reliable
Approved materials in compliance with FDA and EC 1935/2004
Cost effective
Simple, fast setup
User friendly
Simple mounting
Recommended products
VEGAPULS 64
Non-contact radar level measurement in hexane storage tank
Measurement down to the tank bottom, even in media with low dielectric constant
Strong focusing of the radar beam allows exact measurement
Easy installation thanks to small process fittings
Measuring range - Distance
30 m
Process temperature
-196 ... 200 °C
Process pressure
-1 ... 25 bar
VEGASWING 63
Vibrating level switch for point level detection in hexane storage tank
Accurate level detection thanks to adjustment-free, media-independent switching point
An enamel coating guarantees a long service life for the sensor and protects it against corrosive media
Test button for easy testing of instrument functionality during operation
Process temperature
-50 ... 250 °C
Process pressure
-1 ... 64 bar