Differential pressure measurement for filter monitoring
Process data
Measuring task
Differential pressure measurement
Measuring point
Pipe
Measuring range up to
5 m
Medium
Water
Process temperature
0 … +50 °C
Process pressure
0 … +5 bar
Special challenges
Fast response times of the measurement
Application
Often, in the manufacture of pharmaceuticals, substances need to be separated from one another or perhaps some cell components precipitated. One method of doing this is using special filtration systems. When the filter is working properly, the quality and yield of the products are at their optimum. So continuous differential pressure monitoring of the filters ensures the filters are running at their most efficient at all times.
Your benefit
Reliable
Self-monitoring ceramic measuring cell with 3A/EHEDG approval
Cost effective
Efficient operation and cleaning of the filter during continuous operation
User friendly
One measuring system, three measurements: differential pressure, static pressure, temperature
Recommended products
VEGABAR 82
Differential pressure measurement with electronic differential pressure system on the filter
Hygienic process fitting for the pharmaceutical industry
Long-term stability and reliability with moisture-proof measuring cell
One measuring system, three measured values: pipe pressure, medium temperature and differential pressure
Simple mounting and installation
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 100 bar
Process temperature
-40 ... 150 °C