Level measurement in an aluminium powder suspension reactor
Process data
Measuring task
Level measurement
Measuring point
Reactor
Measuring range up to
1.2 m
Medium
Aluminium powder suspension
Process temperature
0 … +130 °C
Process pressure
0 … +0.3 bar
Special challenges
Low dielectric constant, confined spaces, strong turbulence on the product surface, condensation
Application
Aluminium powder suspension is an intermediate for titanium sponge production. In the reactor, vanadium oxide trichloride is removed from the aluminium powder suspension. When the aluminium powder suspension is fed into the reactor, strong turbulence arises on the product surface. To optimize the process, the level in the reactor must be accurately measured and monitored.
Your benefit
Reliable
Reliable measurement despite small dielectric constants
Cost effective
Reliable measurement of the entire reactor volume
User friendly
Simple mounting and setup
Recommended products
VEGAPULS 64
Non-contact level measurement with radar in the reactor
Good signal focussing allows use in tight spaces
Unaffected by condensate and deposits on the antenna
Strong focussing allows reliable measurement at close range and at the bottom of the tank as well as in media with low dielectric constant
Maintenance-free through non-contact measurement
Measuring range - Distance
30 m
Process temperature
-196 ... 200 °C
Process pressure
-1 ... 25 bar