Through circulation and aeration of the wastewater, mineral substances such as grit and sand settle to the bottom of the stilling basin. Equipment breakdown and damage through wear or clogging are prevented by removing the sand.
Recommended Products
VEGAVIB 62
Level detection of settled grit under water
Reliable function through product-independent switching point
Wear and maintenance free operation
Freely moving sensor element and highly durable suspension cable
Process temperature
-40 ... 150 °C
Process pressure
-1 ... 6 bar
Version
Detection of solids in water
Suspension cable
VEGATOR 121
Single channel signal conditioning instrument for level detection
Comprehensive monitoring detects short-circuit and line break of the measuring cable and interferences in the sensor
Simple and comfortable SIL and WHG function test by means of test key
Simple installation through carrier rail mounting as well as detachable, coded terminals
Protection rating
IP 20
Input
1 x sensor input two-wire 8/16 mA
Output
1 x operating relay (SPDT)
Optionally 1 x fail safe relay output (SPDT)
Sorry, Currently No Video Uploaded.
Sorry, Currently No File Uploaded.
Point level detection in a grit trap